Skip to content
Need Help Sleeping? Call us. 1-844-451-6555
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup
Portable Outlet | SKU: PO1600UPSX9

Portable Outlet X9 CPAP Battery Backup

$369.00
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup
Portable Outlet X9 CPAP Battery Backup

Low In Stock, Hurry Up! - Same Day Shipping for orders placed by 2PM EST.

Want to know the full specs?

View All Details
Your total:
$369.00
60-Night Risk Free

Return unopened items for a full refund or store credit (minus return shipping), and opened items for store credit within 60 days.

Free Shipping Over $50
Unlimited Support
Price Match Guarantee

The X9 is a universal CPAP and BiPAP backup battery designed to keep therapy running during power loss or when sleeping away from a wall outlet. It functions as an inline UPS: plug it into the wall, plug your machine into the battery, and the device automatically switches to battery power when an outage occurs. No setup, adapters, or extra cables require.

The system supports all CPAP and BiPAP models because it delivers standard AC power rather than machine-specific DC outputs. This makes it compatible with full-size devices, travel CPAPs, and non-CPAP electronics.

  • Keep the battery fully charged: A full charge before bedtime helps maintain the expected 8–12 hours of CPAP or BiPAP runtime.
  • Disable heated humidity: Turn off the heated humidifier and heated tubing to extend battery life as much as possible.
  • Check your cpap mask seal: Poor seals make the machine work harder, which reduces runtime overnight.
  • Give the battery ventilation: Place it on a hard, open surface and avoid covering the vents to prevent overheating.
  • Stand it upright if warm: If the unit heats up, standing it on its narrow edge improves airflow.
  • Use only the included wall charger: Avoid charging it through USB ports, computers, or third-party cables.
  • Reset after overload: If it shuts down, disconnect everything and wait a few minutes before turning it back on.
  • Keep it dry: Moisture can damage the internal components and shorten battery lifespan.
  • Stay under the 100W limit: Avoid plugging in devices that exceed the battery’s rated output.
  • Use it as a UPS correctly: Leave the battery plugged into the wall with your CPAP connected for automatic outage backup.
  • Turn off the display: If you don’t need the screen lit, turning it off helps save battery power overnight.
  • Avoid cold temperatures: Battery performance drops in cold environments, so keep it insulated when traveling.
  • Store it properly: Keep it in a cool, dry place away from heat and direct sunlight when not in use.
  • Keep ports clean: Dust-free AC and USB ports help maintain stable charging and output.
  • Use a surge protector: When charging at home, using a surge protector helps protect the internal circuitry.
  • Charge early when off-grid: Solar or car charging may take several hours, so plan ahead for overnight use.
  • Avoid soft surfaces: Don’t place the battery on beds, pillows, or carpets that block airflow.
  • Unplug during long breaks: Disconnect CPAP and wall power if you’re storing the battery for a while.
  • Use the travel bag: It protects the battery during transport and helps keep vents clean.
  • Follow basic handling rules: Don’t open, modify, or drop the battery to preserve safety and warranty coverage.

Portable Outlet X9 CPAP Battery Backup

$369.00
$369.00

Product Specifications

Battery Capacity 159 Wh / 14.4 Ah
AC Input 100–240V / 50–60Hz
DC Input 12–19V, 2–3.2A
AC Output 110V / 60Hz (matches AC input)
USB DC Output 5V, 3.0A
Rated / Peak Power Output 100W / 145W
Battery Recharging Time Approximately 5–6 hours
Operating Temperature 40°F to 105°F
Weight 3 lbs
Dimensions 6” W × 9.25” D × 1.5” H

Product Features

Continuous Power Through Outages

The X9 battery sits between the wall outlet and the CPAP or BiPAP unit, passing AC power during normal use. When an outage occurs, it switches to internal battery mode without stopping airflow. The transition maintains ongoing ventilation for the duration of the interruption.

Universal Compatibility Without Extra Adapters

The unit connects to CPAP and BiPAP machines using their standard power cords. No specialized adapters or proprietary cables are required. Voltage input from 100–240V supports use in regions with different electrical standards.

Average Runtime for CPAP Devices

Runtime for CPAP therapy averages 10 to 12 hours at pressures between 4–15 cmH₂O with a standard tube and passover humidification. Travel CPAP devices, which draw less power, commonly reach longer runtimes under similar conditions.

overview image

Average Runtime for BiPAP Devices

BiPAP systems operating around 10/15 cmH₂O typically run for 8 to 10 hours on the X9 with standard tubing and passover humidification. This range reflects the higher power draw associated with dual-pressure operation.

Scalable Runtime With Second Battery

A second X9 battery can be connected to increase total runtime. The pairing maintains the same operating method and compatibility while doubling available capacity for extended therapy or higher-demand settings.

USB-A and USB-C Charging Outputs

USB-A and USB-C ports supply 5V/3.0A output for small electronics. These ports function independently of the CPAP connection and can be used during both AC passthrough and battery operation.

Off-Grid Charging via Solar or Car Adapter

The X9 can recharge through a compatible solar panel or car adapter when AC outlets are unavailable. These charging options support use in remote locations or during prolonged outages.

Pure Sine Wave Output for Device Safety

AC output is delivered as a pure sine wave, matching the waveform of standard household power. This type of output is suitable for medical motors and electronics that require stable electrical input.

Display Indicators for Real-Time Monitoring

The integrated display shows remaining battery percentage, operating mode, and charging status. The screen provides continuous access to the unit’s current state without external monitoring tools.

Air Travel–Compliant Battery Size

With a capacity of 159 Wh, the X9 meets TSA and FAA requirements for carry-on lithium-ion batteries. The device can be transported in cabin luggage without special documentation.

Recharge Time

A full recharge takes approximately 5 to 6 hours using the included wall cord. Both AC and DC inputs follow this charging timeframe.

Durable Travel Bag Included

The included soft travel bag stores the battery and its accessories. It offers surface protection from scratches and minor impacts during transport.

Electrical Output and Load Capacity

The unit provides 100W continuous output with a 145W peak. The AC output is regulated at 110V/60Hz, and the USB ports maintain 5V/3.0A delivery.

Environmental Operating Range

Operational temperature limits extend from 40°F to 105°F. The battery remains within safe performance parameters throughout this range.

Compact Dimensions for Portability

At 6 inches wide, 9.25 inches deep, and 1.5 inches high, the device fits easily into backpacks and medical travel bags used for portable therapy setups.

One-Year Replacement Warranty

The X9 includes a one-year replacement warranty covering defects under normal use conditions. Coverage parameters apply to the battery and included components.

FAQs

I'm not sure if I have sleep apnea

Not sure if you have sleep apnea?

Take this simple test to know your risk level.

Find Solution

How long does a CPAP run on the X9 battery?

Most CPAP machines run 10 to 12 hours on the X9 when using average pressures (4–15 cmH₂O) with a standard tube and passover humidifier. BiPAP devices typically run 8 to 10 hours at average settings (10/15 cmH₂O). Travel CPAPs tend to last longer, often reaching 16+ hours because they draw less power.

Can the X9 power any CPAP or BiPAP machine?

Yes, the X9 works with all CPAP and BiPAP models because it outputs standard AC power and does not require brand-specific cables or adapters. Devices plug in using their normal power supply, making it compatible with ResMed, Philips, Fisher & Paykel, and all travel CPAP systems.

Is the X9 safe for air travel and TSA compliant?

The X9’s 159 Wh capacity meets TSA and FAA requirements for carry-on batteries under 160 Wh. It must be packed in carry-on luggage, and airlines may require approval for batteries carried as spares. CPAP batteries are typically allowed onboard for medical use.

Can I use the X9 during a power outage as a UPS?

Yes. When plugged into the wall, the X9 passes power through during normal use and automatically switches to battery mode if the power fails. The transition is uninterrupted, so airflow continues without stopping. This makes it suitable as an emergency UPS for nightly therapy.

Does the X9 support devices with heated tubing or humidifiers?

The runtime is shorter when using heated tubing or active humidification. Many users turn humidity off or to “passover” mode to maximize hours. A second X9 battery can extend total runtime for setups that require both heating elements.

Can the X9 be used for camping or off-grid travel?

Yes. The X9 can power CPAP therapy while camping, and its USB-A and USB-C ports allow charging phones or tablets. It can also be recharged using a compatible solar panel or 12V car charger, which helps during extended off-grid use.

Can I charge other electronics with the X9 while running my CPAP?

Yes. The X9 can run a CPAP machine and charge two USB devices at the same time (5V/3.0A). It also supports small AC electronics such as laptops, radios, or portable fans, as long as they remain under the 100W continuous output limit.

How long does the X9 take to recharge?

Recharge time is typically 5 to 6 hours when plugged into a wall outlet. The unit includes a standard thin wall cord and can also recharge through compatible car or solar inputs (12–19V, 2–3.2A).

Can I use a regular power bank instead of this battery to run a CPAP?

Most phone or laptop power banks cannot run a CPAP because they do not provide sufficient wattage or AC output. CPAP machines generally require 30–60W, and some models need more during ramp or humidifier use. The X9 provides 100W rated output, which covers all mainstream devices.

Is the X9 suitable as a backup battery for BiPAP machines?

Yes. The battery supports all BiPAP machines using standard AC input. At average BiPAP pressures (10/15 cmH₂O), typical runtime is 8–10 hours. High-pressure settings or heated components may reduce total hours.

Does the X9 meet international voltage requirements?

Yes. The AC input of 100–240V / 50–60Hz supports worldwide voltages, making the battery suitable for international travel without a separate converter. Plug adapters may still be needed depending on the destination.

What are the operating conditions for the X9 battery?

The battery operates between 40°F and 105°F, making it suitable for most indoor and mild outdoor environments. Extreme cold may reduce runtime for lithium-based batteries.

Is the X9 a good choice for CPAP battery camping setups?

For single-night camping, the X9 is often sufficient on its own due to its 159 Wh capacity. For multiple nights or for setups using heated humidifiers, many campers pair the X9 with a solar recharging panel or carry a second battery.

Our CPAP Experts are here to help you.

With exclusive deals, recommendations, or support at any step of your CPAP journey.

  • Icon Text Us
Chat Now
Bryan S.
Daniel F.
Gabriel G.
Stacy K.
Iara R.

"There’s nothing better than hearing a customer say, ‘I finally feel rested again."

"Every CPAP journey is unique, and we love helping users find solutions that work for them."

"I love helping patients find the right CPAP setup—better sleep makes a huge difference."

"Having questions is a normal part of the CPAP journey. We’re here to help every step of the way"

“At Sleeplay.com, I’m proud to support customers on their health journey by making sure they have access to the right tools for better sleep and breathing.”

Questions? - Call Us!: (844) 841-6555