Skip to content
Need Help Sleeping? Call us. 1-844-451-6555
ResMed AirTouch F30i Full Face Mask Replacement Frame front view
ResMed AirTouch F30i Full Face Mask Replacement Frame back view
ResMed AirTouch F30i Full Face Mask Replacement Frame side view
ResMed AirTouch F30i Full Face Mask Replacement Frame side view
ResMed AirTouch F30i Full Face CPAP Mask cushion and frame size
ResMed AirTouch F30i Full Face CPAP Mask parts size
Resmed | SKU: 62477

ResMed AirTouch F30i Full Face Mask Replacement Frame

$134.00
ResMed AirTouch F30i Full Face Mask Replacement Frame front view
ResMed AirTouch F30i Full Face Mask Replacement Frame back view
ResMed AirTouch F30i Full Face Mask Replacement Frame side view
ResMed AirTouch F30i Full Face Mask Replacement Frame side view
ResMed AirTouch F30i Full Face CPAP Mask cushion and frame size
ResMed AirTouch F30i Full Face CPAP Mask parts size

Low In Stock, Hurry Up! - Ships Next Business Day.

Size
Your total:
$134.00
60-Night Risk Free

Return unopened items for a full refund or store credit (minus return shipping), and opened items for store credit within 60 days.

Free Shipping Over $50
Unlimited Support
HSA/FSA Approved

Select Icon at checkout to pay directly with your FSA/HSA card and skip the reimbursement process.

Price Match Guarantee

The AirTouch F30i Clear Frame is a replacement system of the AirTouch F30i Full Face CPAP/BiPAP system. It works as a central support for the cushion, elbow, and headgear of the mask, and helps to maintain the internal air channel that delivers therapy pressure from the CPAP or BiPAP machine to the mask interface.

The frame is built from medical-grade polycarbonate designed for high impact resistance and stability under continuous positive airway pressure up to 30 cm H₂O. Its top-of-head connector includes a 360° rotating swivel made of thermoplastic elastomer (TPE) and polypropylene for unrestricted tubing movement and consistent pressure flow across multiple sleep positions.

The assembly is interchangeable with the AirFit F30i (magnetic version) and supports ComfiSoft and AdaptiSeal cushions from the AirTouch F30i series. Magnet housings are made with nickel-plated neodymium magnets, encapsulated in polymer for safety and corrosion resistance.

All materials are BPA-free, phthalate-free, and latex-free. Magnet safety guidelines specify maintaining at least 150 mm (6 in) distance from active implanted medical devices.

  • Confirm compatibility before purchase: Make sure the Clear Frame is designed for the AirTouch F30i or AirFit F30i magnetic version and matches your cushion type and size.
  • Use the frame sizing guide: Reference ResMed’s sizing template to select Small, Standard, or Large frame sizes that correspond to your cushion dimensions.
  • Check your cushion pairing: Pair the frame with the correct cushion size (Small-Wide, Medium, or Large) to ensure a proper seal and avoid leaks.
  • Inspect the package before use: Verify that the frame and swivel are free from cracks, scratches, or defects that might affect performance.
  • Assemble carefully: Attach the cushion, elbow, and headgear following alignment guides to maintain the internal airflow channel.
  • Follow magnet safety rules: Maintain a minimum 6-inch (150 mm) distance from pacemakers or metallic implants due to the magnetic clips.
  • Clean weekly: Wash the frame with warm water and mild detergent, then rinse thoroughly to remove any soap residue.
  • Avoid harsh cleaning products: Alcohol, bleach, or abrasive brushes can damage the polycarbonate or the swivel seals.
  • Allow complete drying: Always air-dry the frame fully before reassembly to prevent trapped moisture or bacterial growth.
  • Use the 360° swivel efficiently: Position the top-of-head tube to reduce drag and allow comfortable movement during sleep.
  • Do not overtighten the headgear: The frame is designed to work with minimal strap tension; over-tightening can affect fit and airflow balance.
  • Check vent and seal alignment: Make sure the cushion’s QuietAir vents are unobstructed and the frame locks securely into place.
  • Store in a clean environment: Keep the frame in a dry, cool area, away from direct sunlight or moisture that could deform the material.
  • Replace every three months: Regular replacement maintains seal performance and airflow stability, especially with nightly use.
  • Protect during travel: Use a soft or hard travel case to avoid bending or cracking the frame when packing it.
  • Use only compatible parts: Always pair the frame with AirTouch F30i or AirFit F30i cushions and magnetic headgear for proper fit and performance.
  • Monitor pressure and airflow: After connecting, listen for leaks or uneven airflow, indicators of improper assembly or wear.
  • Check comfort after setup: If pressure points or leaks appear around the cheeks or nose, reassess cushion size instead of tightening the straps.
  • Inspect magnetic clips regularly: Confirm that both clips attach smoothly and remain free of corrosion or wear.
  • Keep a spare frame available: Having a backup ensures uninterrupted therapy if your main frame becomes damaged or worn over time.

ResMed AirTouch F30i Full Face Mask Replacement Frame

$134.00
$134.00

Product Features

Compatibility with AirTouch F30i and AirFit F30i Masks

The clear frame is designed specifically for the AirTouch F30i mask system and is also compatible with the AirFit F30i (magnetic variant only). It connects with AirTouch F30i cushions using a keyed locking system that aligns the internal air channels and QuietAir vent array. All exhaust airflow is directed exclusively through the cushion’s integrated diffuser, which preserves the low acoustic profile of approximately 20 dBA and ensures stable pressure delivery without additional venting points.

Frame Construction and Airflow Engineering

The AirTouch F30i Clear Frame is a replacement designed to support the cushion and headgear of the AirTouch F30i and AirFit F30i (magnetic variant) masks. Its internal air channel is molded from polycarbonate, chosen for its dimensional stability, impact resistance, and lightweight properties. The frame distributes incoming airflow symmetrically to both cushion sides, ensuring pressure uniformity across the full operational range of 4–30 cm H₂O. Mechanical load and fatigue testing confirm over 100,000 connect/disconnect cycles without measurable deformation, maintaining seal consistency and alignment under repeated use.

Medical-Grade Materials and Safety Standards

Each frame component is manufactured from biocompatible materials, including polycarbonate, thermoplastic elastomer (TPE), and polypropylene. Magnetic clips use nickel-plated neodymium magnets enclosed in polymer housings for durability. All parts are BPA-free, phthalate-free, and latex-free, tested under ISO 10993-1 and 10993-10 for prolonged skin contact, and certified as FDA Class II and CE-MDR 2017/745 compliant.

overview image

Pressure Stability and Flow Resistance Control

The internal frame geometry maintains laminar airflow and reduces turbulence as air passes to the cushion. Flow-bench validation shows consistent pressure within ±0.5 cm H₂O at therapeutic levels, ensuring uniform delivery across both sides of the mask. This design meets ISO 5356-1 22 mm hose standards, ensuring universal compatibility with most CPAP tubing systems.

Magnetic Connection and Headgear Interface

The headgear attaches via magnetic clips housed in corrosion-resistant nickel-plated casings. Each connector maintains stable field strength and mechanical alignment through repeated use cycles. In accordance with ResMed’s 2024 safety labeling, users should maintain a minimum 150 mm (6 in) separation between the mask magnets and any implanted medical devices.

Performance Under Thermal and Environmental Stress

The frame remains mechanically stable under operating conditions from +5 °C to +40 °C and humidity between 15 % and 95 % non-condensing. Storage tolerance extends from –20 °C to +60 °C without material deformation or loss of sealing precision. Testing simulating home and travel use confirmed long-term resistance to thermal cycling, vibration, and mechanical load.

Cleaning and Maintenance Guidelines

Routine care involves weekly cleaning with warm water and mild detergent followed by air-drying. The frame should not be exposed to direct heat or alcohol-based cleaners, which can degrade the swivel seals and surface finish. Periodic inspection of the connectors and swivel joint helps maintain consistent airflow and structural integrity during nightly use.

Recommended Replacement Schedule

ResMed recommends replacing the AirTouch F30i Clear Frame every three months. Over time, mechanical fatigue, micro-abrasion, and reduced joint elasticity can alter fit precision and affect pressure delivery. Scheduled replacement maintains the intended airflow dynamics and compliance with noise and leak performance standards. Check out our replacement parts page in the footer.

Certification and Quality Assurance

Manufactured under ISO 13485 medical device quality standards, the frame undergoes dimensional and fatigue testing exceeding 100,000 connect/disconnect cycles. All materials are traceable by lot, and production adheres to MDR and FDA documentation requirements, ensuring consistent reliability and safety for clinical and home environments.

Functional Role in CPAP and BiPAP Therapy

The AirTouch F30i Clear Frame provides the physical and pneumatic link between the tubing, cushion, and headgear. By stabilizing pressure flow and maintaining geometric alignment, it ensures efficient transfer of therapeutic pressure throughout the breathing cycle. The clear-frame variant omits textile wrapping for improved hygiene, faster drying, and easy visual inspection, ideal for long-term users requiring consistent airflow and structural performance.

How to Use

How to Fit the Resmed Airtouch F30i Clear Full Face CPAP Mask
image

How to Fit the Resmed Airtouch F30i Clear Full Face CPAP Mask

Expert Tips & Vídeos

FAQs

I'm not sure if I have sleep apnea

Not sure if you have sleep apnea?

Take this simple test to know your risk level.

Find Solution

Which masks is the AirTouch F30i frame compatible with?

The AirTouch F30i Clear Frame is designed for the AirTouch F30i mask and is compatible with the AirFit F30i magnetic version. It supports ComfiSoft™ and AdaptiSeal™ cushions from the F30i series and connects through the same locking system that aligns the internal air channels and QuietAir™ vent array.

What frame sizes are available for the AirTouch F30i?

The AirTouch F30i frame comes in three sizes (Small, Standard, and Large) to match different cushion and facial configurations. Correct sizing ensures proper fit and pressure distribution. You can confirm the right frame size using the downloadable sizing guide in the Resources section of the product page.

How do I match the frame to the right cushion size?

Each frame size pairs with specific cushion sizes as follows: Small Frame: for Small-Wide or Medium cushions Standard Frame: for Small-Wide, Medium, or Large cushions Large Frame: for Medium or Large cushions Using the correct combination maintains seal alignment and stable airflow during therapy.

Can the AirTouch F30i frame be used with the non-magnetic AirFit F30i version?

No. Compatibility applies only to the standard magnetic AirFit F30i frame. The non-magnetic version has not been validated for interchangeability.

How often should I replace the AirTouch F30i frame?

ResMed recommends replacing the frame approximately every three months. Frequent use and cleaning can cause gradual fatigue in the swivel joint or minor structural wear that affects pressure stability and alignment.

How should I clean the AirTouch F30i frame?

Clean the frame weekly using warm water (30–40 °C) and mild liquid detergent. Rinse thoroughly with drinking-quality water and let it air-dry completely away from sunlight or heat. Avoid dishwashers, boiling water, or alcohol-based products.

Can I use alcohol wipes or brushes to clean the frame?

No. Abrasive brushes or alcohol wipes can cause surface damage and stress cracks in the polycarbonate, affecting durability and airflow sealing.

How do I maintain the swivel and vent alignment?

Check that the 360° swivel rotates smoothly. If movement feels restricted or noisy, clean gently. Make sure the vent alignment area that connects to the cushion’s QuietAir™ diffuser is free from debris or residue to maintain consistent pressure flow.

Are the magnets safe to use around medical implants?

Yes, but users with pacemakers or defibrillators must maintain at least a 6-inch (150 mm) distance between the frame’s magnetic clips and any implanted medical device, following ResMed’s safety guidelines.

Why shouldn’t I expose the frame to high heat or sanitizers?

Heat above 60 °C or UV-based cleaners can warp the polycarbonate and TPE materials, damaging the swivel seals or frame alignment. Always air-dry at room temperature after cleaning.

How do I know which AirTouch F30i frame size I need?

Frame size is determined by your cushion size. The Small frame fits Small-Wide and Medium cushions, the Standard frame fits all cushion sizes (Small-Wide, Medium, Large), and the Large frame fits Medium and Large cushions. Use the printed sizing guide available in the Resources section of the product page for confirmation.

Are the frame sizes interchangeable between cushions?

Only within specific pairings. You cannot mix a Large cushion with a Small frame, or a Small-Wide cushion with a Large frame. Frame and cushion sizes are engineered to align airflow channels and vent placement, so proper pairing is essential for sealing accuracy and comfort.

What is the difference between Small, Standard, and Large frames?

The frame size defines the width and height of the airflow channel and the distance between the magnetic clips. A Small frame is slightly shorter and narrower, while a Large frame has extended dimensions to fit wider facial structures. The Standard frame provides a balanced fit for most users.

Does the frame size affect therapy pressure or performance?

Yes. Using a mismatched frame and cushion can cause uneven pressure distribution or leaks, especially around the cheeks and nose. Selecting the correct frame ensures stable airflow, accurate therapy pressure, and reduced noise.

How can I check my current frame size?

Look at the inside of the frame near the elbow connector—ResMed prints the frame size (S, STD, or L) in small lettering. If the label has worn off, compare your frame to the sizing chart in the downloadable guide or check the cushion-frame pairing on your packaging.

What does “Small-Wide” mean for F30i cushions?

“Small-Wide” refers to a cushion that is shorter vertically but wider horizontally across the mouth area. It is designed for users with smaller nose height but broader facial width. It pairs best with Small or Standard frames depending on your facial dimensions.

Can I use an AirFit F30i frame with an AirTouch F30i cushion of a different size?

Yes, if both are magnetic versions and you respect size compatibility. For example, a Standard AirFit F30i frame can be used with a Medium AirTouch F30i cushion, but not with a size combination outside the verified compatibility chart.

How can I verify fit once assembled?

After connecting the cushion to the frame, the mask should rest under the nose without pressure on the nasal bridge. Air leaks or uneven tension across the cheeks indicate an incorrect size pairing or over-tightened headgear.

Do I need a new headgear size when changing frame size?

Not always. The AirTouch F30i and AirFit F30i use the same headgear system, which adapts across frame sizes. However, users with smaller or larger head shapes may prefer to adjust or replace the headgear to maintain proper alignment.

Where can I find the AirTouch F30i sizing template?

You can download the official ResMed F30i sizing guide in PDF format from the “Resources” section of the AirTouch F30i product page. Print it at 100% scale to accurately determine your cushion and frame combination before ordering.

Our CPAP Experts are here to help you.

With exclusive deals, recommendations, or support at any step of your CPAP journey.

  • Icon Text Us
Chat Now
Bryan S.
Daniel F.
Gabriel G.
Stacy K.
Iara R.

"There’s nothing better than hearing a customer say, ‘I finally feel rested again."

"Every CPAP journey is unique, and we love helping users find solutions that work for them."

"I love helping patients find the right CPAP setup—better sleep makes a huge difference."

"Having questions is a normal part of the CPAP journey. We’re here to help every step of the way"

“At Sleeplay.com, I’m proud to support customers on their health journey by making sure they have access to the right tools for better sleep and breathing.”

Questions? - Call Us!: (844) 841-6555